Vue de la page 0
120V AC Wire-In Smoke Alarm
Slide Load Front Battery Door
Model i4618
Description
The Kidde i4618 is an AC/DC powered, ionization smoke
alarm that operates on a 120V power source with 9V
battery backup.
This alarm uses ionization sensing technology. Ionization
sensing alarms may detect invisible fire particles
(associated with flaming fires) sooner than photoelectric
alarms. Photoelectric sensing alarms may detect visible
particles (associated with smoldering fires) sooner than
ionization alarms.
Kidde strongly recommends that both ionization
and photoelectric smoke alarms be installed to help
insure maximum detection of the various types of
fire that can occur within the home.
The front-loading battery door allows user to change the
battery without removing the alarm from the mounting
bracket making battery replacement easy and convenient.
This smoke alarm is available in a 6-piece cut case with
tray for easy display as well as a 6-piece bulk pack for
contractors and property owners. This unit is a UL Listed
product with a 5-year limited warranty.
Install Confidence:
Easy Installation
Front battery pull tab allows battery activation
without removing alarm from mounting bracket.
Large mounting base makes mounting easier, protects
surface paint from dirt and covers imperfections.
Pre-stripped wiring harness with easy off cap does
not require stripper tool. Tinned strands increase
conductivity and wire nut grip.
Fewer Callbacks
Large centrally located Test/Hush
®
alarm control button.
Dust cover protects sensor from contaminates during
construction reducing nuisance alarms.
User-Friendly Features
Easy access front loading battery door.
Battery backup provides protection in case of
power failure.
Interconnectable with up to 24 devices (of which 18
can be initiating) including smoke, CO and heat
alarms. See user’s guide for complete instructions.
Ionization Sensing Technology
Battery Backup (batteries included)
Hush
®
Button
Alarm Memory Indicator
New 360˚ Mounting Plate
with Tamper Resistance
Front Load Battery Door
Vue de la page 0
1 2

Résumé du contenu

Page 1 - 120V AC Wire-In Smoke Alarm

120V AC Wire-In Smoke Alarm Slide Load Front Battery DoorModel i4618 DescriptionThe Kidde i4618 is an AC/DC powered, ionization smoke alarm that oper

Page 2 - Installation of Smoke Alarm

Architectural and EngineeringSpecifications The smoke alarm shall be Kidde Model i4618 or approved equal. It shall be powered by a 120VAC, 60Hz sourc